With the advent of energy-saving era, energy-saving air compressor is one of the main mechanical power equipment in many enterprises. Therefore, it is very necessary to maintain the safe operation of air compressor. Strictly implementing the operating procedures of the air compressor will not only help to prolong the service life of the air compressor, but also ensure the safety of the air compressor operators.
Now let's understand the correct operation steps of the lower air compressor.
1、 Before the operation of the air compressor, pay attention to the following problems: keep the lubricating oil in the oil pool within the scale range, and check that the oil quantity in the oiler shall not be lower than the scale mark before the operation of the air compressor. Check whether the moving parts are flexible, whether the connecting parts are fastened, whether the lubrication system is normal, and whether the motor and electrical control equipment are safe and reliable. Before the operation of the air compressor, check whether the protective devices and safety accessories are intact and complete. Check whether the exhaust pipeline is unblocked. Connect the water source and open each inlet valve to make the cooling water unblocked.
2、 During the operation of the air compressor, attention shall be paid to turning inspection after long-term shutdown and before the first start, and attention shall be paid to whether there is impact, jamming or abnormal sound.
3、 The machine must be started under idle-load condition. After the idle-load operation is normal, gradually put the air compressor into load operation.
4、 During the operation of the air compressor, after normal operation, always pay attention to the readings of various instruments and adjust them at any time.
Sazhen energy saving air compressor, for more information, please consult www.shkyj.com com
5、 During the operation of the air compressor, the following conditions shall also be checked: whether the motor temperature is normal and whether the reading of each ammeter is within the specified range. Check whether the operation sound of all parts is normal. Whether the suction valve cover is heated and whether the sound of the valve is normal. Whether various safety protection equipment of air compressor are reliable.
6、 After the air compressor operates for 2 hours, the oil and water in the oil-water separator, intercooler and aftercooler shall be discharged once, and the oil and water in the air storage bucket shall be discharged once per shift.
7、 When the following conditions are found during the operation of the air compressor, stop it immediately, find out the causes and eliminate them.
1. The lubricating oil is finally cut off or the cooling water is finally cut off.
2. The water temperature suddenly rises or drops
3. The exhaust pressure rises suddenly and the safety valve fails.